Same day dispatch on all stocked items.
The EDS-205A/208A series are 5 and 8-port industrial Ethernet switches that support IEEE 802.3 and IEEE 802.3u/x with 10/100M full/half-duplex, MDI/MDI-X auto-sensing. The EDS-205A/208A switches provide 12/24/48 VDC (9.6 to 60 VDC), 18 to 30 VAC redundant power inputs that can be connected simultaneously to live AC/DC power sources. These switches have been designed for harsh industrial environments, such as in maritime (DNV/GL/LR/ABS/NK), rail wayside, highway, or mobile applications(EN 50121-4/NEMA TS2/e-Mark), or hazardous locations (Class I Div. 2, ATEX Zone 2) that comply with FCC, UL, and CE standards.
The EDS-205A/208A switches are available with a standard operating temperature range from -10 to 60°C, or with a wide operating temperature range from -40 to 75°C. All models are subjected to a 100% burn-in test to ensure that they fulfill the special needs of industrial automation control applications. In addition, the
EDS-205A/208A switches have DIP switches for enabling or disabling broadcast storm protection, providing another level of flexibility for industrial applications.
| Technology | |
| Standards | IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) and 100BaseFX IEEE 802.3x for Flow Control |
| Processing Type | Store and Forward |
| Flow Control | IEEE 802.3x flow control, back pressure flow control |
| Switch Properties | |
| MAC Table Size | 1 K |
| Packet Buffer Size | 512 kbit |
| Interface | |
| Fiber Ports | 100BaseFX ports (SC/ST connector, multi-mode, single-mode) |
| RJ45 Ports | 10/100BaseT(X) auto negotiation speed, Full/Half duplex mode, and auto MDI/MDI-X connection |
| DIP Switches | Enable/Disable broadcast storm protection |
| LED Indicators | Power, 10/100M (TP port), 100M (fibre port) |
| Optical Fiber | |
| Table | ![]() |
| Power Requirements | |
| Input Voltage | 12/24/48 VDC (9.6 to 60 VDC), 18 to 30 VAC (47 to 63 Hz), redundant dual inputs |
| Input Current | EDS-205A: 0.1 A @ 24 V EDS-205A-M/S: 0.11 A @ 24 V EDS-208A: 0.13 A @ 24 V EDS-208A-M: 0.17 A @ 24 V EDS-208A-MM/SS: 0.22 A @ 24 V |
| Overload Current Protection | 1.1 A |
| Connection | 1 removable 4-contact terminal block |
| Reverse Polarity Protection | Present |
| Physical Characteristics | |
| Housing | Aluminum, IP30 protection |
| Dimensions | EDS-205A Series: 30 x 115 x 70 mm (1.18 x 4.52 x 2.76 in) EDS-208A Series: 50 x 115 x 70 mm (1.96 x 4.52 x 2.76 in) |
| Weight | EDS-205A Series: 175 g EDS-208A Series: 275 g |
| Installation | DIN-rail mounting, wall mounting (with optional kit) |
| Environmental Limits | |
| Operating Temperature | Standard Models: -10 to 60°C (14 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
| Storage Temperature | -40 to 85°C (-40 to 185°F) |
| Ambient Relative Humidity | 5 to 95% (non-condensing) |
| Standards and Certifications | |
| Safety | UL 508 |
| Hazardous Location | UL/cUL Class 1 Division 2 Groups A/B/C/D, ATEX Zone 2 Ex nA nC IIC T4 Gc |
| EMI | FCC Part 15 Subpart B Class A, EN 55022 Class A |
| EMS | EN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 3, EN 61000-4-4 (EFT) Level 3, EN 61000-4-5 (Surge) Level 3, EN 61000-4-6 (CS) Level 3, EN 61000-4-8, EN 61000-4-11 |
| Marine | DNV, GL, LR, ABS, NK |
| Wheeled Vehicles | e-Mark (E1) (EDS-208A only) |
| Traffic Control | NEMA TS2 |
| Rail Traffic | EN 50121-4 |
| Shock | IEC 60068-2-27 |
| Freefall | IEC 60068-2-32 |
| Vibration | IEC 60068-2-6 |
| MTBF (mean time between failures) | |
| Time | EDS-205A Series: 3,040,784 hrs EDS-208A Series: 2,428,212 hrs |
| Database | Telcordia (Bellcore), GB |
| Warranty | |
| Warranty Period | 5 years |
| Details | See www.moxa.com/warranty |