Overview
The Moxa EDS-208A-SS-SC is an 8-port compact unmanaged industrial Ethernet switch with 6 x 10/100BaseT(X) copper ports and 2 x 100BaseFX single-mode (SC). Designed for harsh industrial environments, the EDS-208A Series carries a comprehensive certifications stack covering hazardous locations (ATEX, Class I Division 2), maritime (DNV, LR, ABS, NK), rail (EN 50121-4), and traffic control (NEMA TS2) applications. Standard operating temperature range of -10 to 60 deg C.
Key Features
- 6 x 10/100BaseT(X) RJ45 copper ports with auto MDI/MDI-X and auto-negotiation
- Two x 100BaseFX single-mode fibre port(s) with SC connector(s)
- Typical fibre distance: 40 km typical
- IEEE 802.3 / 802.3u / 802.3x compliant, store-and-forward switching
- 2K MAC address table, 768-kbit packet buffer
- DIP-switchable broadcast storm protection
- Redundant dual 12/24/48 VDC power inputs (9.6 to 60 VDC operating range) on removable 4-contact terminal block
- Overload current protection and reverse polarity protection on both power inputs
- Aluminium housing, IP30 rated
- Operating temperature: -10 to 60 deg C (14 to 140 deg F)
- Hazardous locations: ATEX, Class I Division 2
- Maritime: DNV, LR, ABS, NK
- Rail / Traffic: EN 50121-4, NEMA TS2
- Safety: UL 508, EN 62368-1 (LVD)
- Telcordia Bellcore / GB MTBF: 2,705,157 hrs
- 100% burn-in tested on every unit before shipment
- DIN-rail mountable; WK-46-01 wall-mount kit and RK-4U 19-inch rack-mount kit available
- 5-year manufacturer warranty
Applications
- Plant-floor cell aggregation with fibre uplink to the plant backbone
- Rail and traffic-control cabinets requiring NEMA TS2 / EN 50121-4 certification
- Maritime deployments on vessels or offshore platforms (DNV, LR, ABS, NK)
- Hazardous-location installations in ATEX Zone 2 or Class I Division 2 atmospheres
- Utility substations with SCADA telemetry aggregation on a redundant-power switch
- Remote I/O and sensor aggregation in outdoor enclosures (wide-temp -T variants)
- Process monitoring and SCADA in heavy-industry sites with stringent compliance requirements
Fibre Optic Parameters
| Parameter |
Value |
| Fibre standard |
100BaseFX, single-mode |
| Fibre cable |
G.652 single-mode |
| Fibre connector |
SC |
| Wavelength |
1310 nm (1280 to 1340 nm Tx range) |
| Tx power range |
0 to -5 dBm |
| Rx sensitivity |
-3 to -34 dBm |
| Link budget |
29 dB |
| Dispersion penalty |
1 dB |
| Typical distance |
40 km typical |
Note: when using a single-mode fibre transceiver, consider an attenuator on short links to prevent damage caused by excessive optical power.
What’s Included
- 1 x EDS-208A-SS-SC 8-port unmanaged industrial Ethernet switch
- 1 x quick installation guide
- 1 x warranty card
DIN-rail 24 VDC power supplies (MDR-40-24, MDR-60-24, HDR-60-24, NDR-120-24), 48 VDC supplies (NDR-120-48, NDR-240-48), wall-mount kit (WK-46-01), and 19-inch rack-mount kit (RK-4U) available as separately ordered accessories.
Installation & Power Redundancy
The switch mounts to a standard 35 mm DIN rail. Power is supplied via a removable 4-contact terminal block at 12, 24, or 48 VDC nominal (9.6 to 60 VDC operating range) with two redundant inputs – both can be connected simultaneously to live DC power sources. Either input alone can carry the switch; loss of one input does not interrupt service. Overload current protection and reverse polarity protection are built in. A DIP switch on the housing controls broadcast storm protection (enable to rate-limit broadcast frames).