The IMC-101G industrial gigabit modular media converters are designed to provide reliable and stable 10/100/1000BaseT(X) to 1000BaseSX/LX/LHX/ZX media conversion in harsh industrial environments. The IMC-101G’s industrial design is excellent for keeping your industrial automation applications running continuously, and each IMC-101G converter comes with a relay output warning alarm to help prevent damage and loss. All IMC-101G models are subjected to a 100% burn-in test, and are available in models that support a standard operating temperature range of 0 to 60°C, and an extended operating temperature range of -40 to 75°C.
Technology | |
Standards | IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) and 100BaseFX IEEE 802.3ab for 1000BaseT(X) IEEE 802.3z for 1000BaseSX/LSX/LX/LH/LHX/ZX/E2X |
Interface | |
Fiber Ports | 1000BaseSFP slot |
LED Indicators | PWR1, PWR2, FAULT, 10/100M (TP port), 1000M (TP and Fiber port) |
DIP Switches | Port break alarm mask, Link Fault Pass-through, SFP Auto/Force |
Alarm Contact | One relay output with current carrying capacity of 1 A @ 24 VDC |
RJ45 Ports | 10/100/1000BaseT(X) |
Optical Fiber | |
Note | See the SFP-1G series product information on page 3-17 for detailed spec information. |
Physical Characteristics | |
Housing | Metal, IP30 protection |
Dimensions | 53.6 x 135 x 105 mm (2.11 x 5.32 x 4.13 in) |
Weight | 630 g |
Installation | DIN-Rail mounting, wall mounting (with optional kit) |
Environmental Limits | |
Operating Temperature | Standard Models: 0 to 60°C (32 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
Power Requirements | |
Input Voltage | 12 to 45 VDC redundant inputs |
Input Current | 110 mA @ 24 VDC |
Connection | Removable terminal block |
Overload Current Protection | 2.5 A |
Reverse Polarity Protection | Present |
Standards and Certifications | |
Safety | UL 508 |
Hazardous Location | UL/cUL Class I Division 2 Groups A/B/C/D, ATEX Zone 2 Ex nC nL IIC T4, IECEx |
EMC | CE, FCC |
EMI | FCC Part 15 Subpart B Class A, EN 55022 Class A |
EMS | EN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 3, EN 61000-4-4 (EFT) Level 3, EN 61000-4-5 (Surge) Level 2, EN 61000-4-6 (CS) Level 3, EN 61000-4-8, EN 61000-4-11 |
Shock | IEC 60068-2-27 |
Freefall | IEC 60068-2-32 |
Vibration | IEC 60068-2-6 |
Green Product | RoHS, CRoHS, WEEE |
MTBF (mean time between failures) | |
Time | 500,540 hrs |
Database | Telcordia (Bellcore), GB |
Warranty | |
Warranty Period | 5 years |
Details | See www.moxa.com/warranty |